Skip to main content

ESKAP Power Quality

System solutions and services for optimizing power quality and resolving voltage issues.

Leverage our expertise to solve your power grid issues, ensure stable production operations, and effectively reduce costs.

ESKAP Power Quality Analyses

Get to the bottom of grid disturbances with our ESKAP Power Quality Analyses.

Troubleshooting is recommended in the event of the following grid issues:

Faults in control and automation systems

  • Malfunctions in frequency converters
  • Luminance fluctuations
  • Light flickering
  • Defective power factor correction systems
  • Nuisance tripping of protective devices
  • Exceeding agreed power limits
  • Transformer overload
  • Issues caused by grid resonances

Using our mobile or permanently installed power quality analyzers, we investigate existing problems in accordance with applicable standards (EN 50160, EN 61000-2-x) and provide customized solutions for remediation.

Services
  • Detailed, problem-oriented grid analyses according to standard specifications
  • Short-term measurements for on-site troubleshooting
  • Dimensioning and recommendation of customized corrective measures
Fields of Application
  • Equipment / Load Malfunctions
  • Verification Measurements According to Standard Specifications
  • Compliance with Compatibility Levels

ESKAP Power Quality Filter

Harmonics and resonances are feedback effects that cause significant problems in modern electrical grids and installations. This is driven by the decline of installed conventional loads and the rapidly increasing use of frequency-controlled loads.

To ensure stable operation of connected equipment, additional measures must be taken to limit grid feedback to acceptable levels
(EN 50160 / EN 61000-2-x).

This reduces the risk of significantly increased distribution losses and the resulting overheating of cables and transformers. In addition, accelerated aging and the failure risk of electronic loads are minimized.

Failure to take these measures can quickly result in substantial financial losses due to production downtime or the loss of warranty claims.

ESKAP PQi ACTIVE –
Active Power Conditioner

Our efficient plug & play solution for broadband reduction of the most common grid feedback up to approx. 5 kHz with intelligent real-time impedance correction and resonance damping to improve your power supply

ESKAP PQi HYBRID –
Hybrid Power Conditioner

The most efficient solution for broadband reduction of the most common grid feedback up to approx. 15 kHz (supraharmonics) with true resonance damping and optimal mitigation of commutation notches

Now Request
Your Free Information

Experiencing issues in your power grid? Our trained technical experts are always happy to assist you personally.

Simply fill out and submit the form.

Your Personal Contacts

Tilman Barth

Managing Director

Marc Gerstner

Managing Director

Markus Gerber

Sales & Technical Support (Field Service)